Essentially this is a test to determine how well the panel is glued together. It is typically referred to as internal bond in industry. The standard way for performing this test is by using a test specimen that is 2 inches square and is pulled apart perpendicular to the faces of the board. This parameter is typically reported in pounds per square inch or pascals upon failure of the board.